Resolution of ITD detection: stochastic vs. exquisite system

Differences in arrival times of a sound at the two ears (Interaural Time Differences, ITDs) are utilized by mammals to determine the location of low-frequency sound source in the horizontal dimension [4]. Simple calculation shows that to achieve psychophysically revealed accuracy of sound localization, binaural auditory system have to detect ITDs in the order of just a few tens of microseconds. It has long been assumed that such remarkable temporal resolution is the result of ITD encoding by systematically organized arrays of fast neurons - “coincidence detectors” that receive inputs from the two ears via axons of variable length - “delay lines” and create a neural “map” of physiological ITDs. However, despite its wide acceptance, an increasing number of recent morphological and physiological studies in mammals report findings that can not be interpreted in the framework of this classical coincidence detector concept (reviewed in [2]). Therefore, neural mechanisms of the mammalian auditory system underlying high-resolution ITD detection are still not fully understood.

Here, we continue to consider an alternative ITD detection mechanism based on a population coding strategy [5], according to which ITDs are encoded by the relative “activity” levels within bilaterally located populations of binaural sluggish (slow) neurons. To implement studied ITD detection mechanism we employ biologically inspired computational model that simulates the behavior of two symmetric neural populations of the auditory system. Every single neuron model of each population has membrane time constant of >1 ms and receives the balanced excitatory-inhibitory (EI) synaptic inputs carrying ITD. The parameters of neuron [3] and synapse [1] models are turned to mimic pure trough-type activity of EI neurons, i.e., no (or minimal) responses occur when “ipsilateral” excitation and “contralateral” inhibition are near coincidence.

Our previous theoretical and modeling studies have shown that precise distribution (oppositely directed linear gradients) of the conductance value of excitatory and inhibitory synapses within each population allows the proposed model to detect ITD with submillisecond precision. It was also revealed that presence of jitter (related to the dynamic travel time deviation of ipsi- and contralateral signals) or neuronal noise from the physiological range does not have dramatic influence on ITD detection accuracy.

In this work, we focus on the further analysis of stochastic and noise processes in the auditory system and present a computational evidence indicating the necessity to reassess the role of stochasticity in ITD processing. We demonstrate that microsecond order resolution of ITD detection, based on the population coding mechanism, can be accomplished by the auditory system without exquisite tunings of synapses or/and axon lengths. It is also shown that biologically relevant levels of both intrinsic neuronal noise and random time jitter in the synaptic input underlie ITD detection acuity similar to that observed in the model with a precise as well as a random balance of excitatory and inhibitory synaptic inputs. Thus, the results suggest that the considered stochastic processes can play crucial role as complementary/replaceable sources of “perturbation” for the sluggish neuron based populations; that is needed for high-resolution ITD detection.

References

  1. Compte A, Sanchez-Vives MV, McCormick DA, Wang XJ: Cellular and network mechanisms of slow oscillatory activity (<1 Hz) and wave propagations in a cortical network model. J Neurophysiol. 2003, 89 (5): 2707-2725. 10.1152/jn.00845.2002.

    Article  PubMed  Google Scholar 

  2. Grothe B, Pecka M, McAlpine D: Mechanisms of Sound Localization in Mammals. Physiol Rev. 2010, 90: 983-1012. 10.1152/physrev.00026.2009.

    Article  CAS  PubMed  Google Scholar 

  3. Izhikevich EM: Simple model of spiking neurons. IEEE Trans Neural Netw. 2003, 14 (6): 1569-1572. 10.1109/TNN.2003.820440.

    Article  CAS  PubMed  Google Scholar 

  4. Rayleigh L: On our perception of sound direction. Philos Mag. 1907, 13: 214-232.

    Article  Google Scholar 

  5. Van Bergeijk AW: Variation on a theme of Bekesy: a model of binaural interaction. J Acoust Soc Am. 1962, 34: 1431-1437. 10.1121/1.1918364.

    Article  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Viacheslav A Vasilkov.

Rights and permissions

This article is published under license to BioMed Central Ltd. This is an open access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/2.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.

Reprints and permissions

About this article

Cite this article

Vasilkov, V.A., Tikidji-Hamburyan, R.A. Resolution of ITD detection: stochastic vs. exquisite system. BMC Neurosci 12 (Suppl 1), P335 (2011). https://0-doi-org.brum.beds.ac.uk/10.1186/1471-2202-12-S1-P335

Download citation

  • Published:

  • DOI: https://0-doi-org.brum.beds.ac.uk/10.1186/1471-2202-12-S1-P335

Keywords