Skip to main content

Table 1 Single channel parameters estimated from all-points amplitude histograms

From: Evidence for non-independent gating of P2X2 receptors expressed in Xenopusoocytes

[ATP], (μM)

i, (pA)

σex, (pA)

σex/i,

5

2.80 ± 0.1

2.54 ± 0.14

0.90

10

3.36 ± 0.05

2.42 ± 0.09

0.71

15

3.58 ± 0.03

2.31 ± 0.05

0.64

20

3.61 ± 0.03

2.38 ± 0.05

0.66

30

3.54 ± 0.02

2.31 ± 0.04

0.66

50

3.38 ± 0.03

2.30 ± 0.04

0.68

100

3.60 ± 0.02

2.35 ± 0.04

0.65

  1. Note: The results were obtained from the all-points histograms in Figure 5. The relative excess open channel noises of single channel current are similar except the current activated by 5 μM ATP. This outliner is due to the low open probability that make the fitting of Gaussian distribution unreliable.